An outline of all sections included in this SRS is recorded here for easy reference.
This section records information for easy reference.
The unit system used throughout is SI (Système International d'Unités). In addition to the basic units, several derived units are also used. For each unit, the Table of Units lists the symbol, a description, and the SI name.
Symbol | Description | SI Name |
---|---|---|
°C | temperature | centigrade |
m | length | metre |
W | power | watt |
The symbols used in this document are summarized in the Table of Symbols along with their units. The choice of symbols was made to be consistent with the nuclear physics literature and with that used in the FP manual.
Symbol | Description | Units |
---|---|---|
hb | Initial coolant film conductance | -- |
hc | Convective heat transfer coefficient between clad and coolant | \(\frac{\text{W}}{\text{m}^{2}{}^{\circ}\text{C}}\) |
hg | Effective heat transfer coefficient between clad and fuel surface | \(\frac{\text{W}}{\text{m}^{2}{}^{\circ}\text{C}}\) |
hp | Initial gap film conductance | -- |
kc | Clad conductivity | -- |
τc | Clad thickness | -- |
This section first presents the problem description, which gives a high-level view of the problem to be solved. This is followed by the solution characteristics specification, which presents the assumptions, theories, and definitions that are used.
The instance models that govern HGHC are presented in the Instance Model Section. The information to understand the meaning of the instance models and their derivation is also presented, so that the instance models can be verified.
There are no theoretical models.
There are no general definitions.
This section collects and defines all the data needed to build the instance models.
Refname | DD:htTransCladFuel |
---|---|
Label |
Effective heat transfer coefficient between clad and fuel surface |
Symbol | hg |
Units |
\(\frac{\text{W}}{\text{m}^{2}{}^{\circ}\text{C}}\) |
Equation | \[{h_{\text{g}}}=\frac{2\,{k_{\text{c}}}\,{h_{\text{p}}}}{2\,{k_{\text{c}}}+{τ_{\text{c}}}\,{h_{\text{p}}}}\] |
Description |
Refname | DD:htTransCladCool |
---|---|
Label |
Convective heat transfer coefficient between clad and coolant |
Symbol | hc |
Units |
\(\frac{\text{W}}{\text{m}^{2}{}^{\circ}\text{C}}\) |
Equation | \[{h_{\text{c}}}=\frac{2\,{k_{\text{c}}}\,{h_{\text{b}}}}{2\,{k_{\text{c}}}+{τ_{\text{c}}}\,{h_{\text{b}}}}\] |
Description |
There are no instance models.